+48 537 793 935

Concrete culvert headwalls

14 types of reinforced angled headwalls for pipes from Ø200 to Ø1200.

Precast reinforced angled headwalls for the inlet and outlet of a culvert under a driveway or road. Below you will find all types with technical drawings, dimensions and weights.

Number of types
14
Pipe diameters
Ø200–Ø1200
Weight
150–2200 kg
Finished culvert: concrete headwalls with a pipe

Types and dimensions

Click a drawing or photo to enlarge it.

No. 1.1

Angled headwall Ø200

Max. pipe diameter
Ø200 mm
Total width
600 mm
Weight
150 kg
No. 1.2

Angled headwall Ø300

Max. pipe diameter
Ø300 mm
Total width
780 mm
Weight
170 kg
No. 1.3

Angled headwall Ø400

Max. pipe diameter
Ø400 mm
Total width
900 mm
Weight
200 kg
No. 1.4

Angled headwall Ø400

Max. pipe diameter
Ø400 mm
Total width
1600 mm
Weight
380 kg
No. 1.5

Angled headwall Ø500

Max. pipe diameter
Ø500 mm
Total width
930 mm
Weight
260 kg
No. 1.6

Angled headwall Ø500

Max. pipe diameter
Ø500 mm
Total width
1800 mm
Weight
415 kg
No. 1.7

Angled headwall Ø600

Max. pipe diameter
Ø600 mm
Total width
2000 mm
Weight
560 kg
No. 1.8

Angled headwall Ø600 (double reinforcement)

Max. pipe diameter
Ø600 mm
Total width
2200 mm
Weight
790 kg
No. 1.9

Angled headwall Ø600 (double reinforcement)

Max. pipe diameter
Ø600 mm
Total width
3000 mm
Weight
880 kg
No. 1.10

Mountain-type angled headwall Ø600 (double reinforcement)

Max. pipe diameter
Ø600 mm
Total width
2200 mm
Height (adjustable)
1060–1500 mm
Weight
560–1100 kg
No. 1.11

Angled headwall Ø800 (double reinforcement)

Max. pipe diameter
Ø800 mm
Total width
2000 mm
Weight
1060 kg
No. 1.12

Angled headwall Ø1000 (double reinforcement)

Max. pipe diameter
Ø1000 mm
Total width
2000 mm
Weight
960 kg
No. 1.13

Angled headwall Ø1000 (double reinforcement)

Max. pipe diameter
Ø1000 mm
Total width
3000 mm
Weight
1570 kg
No. 1.14

Angled headwall Ø1200 (double reinforcement)

Max. pipe diameter
Ø1200 mm
Total width
3000 mm
Weight
2200 kg
Angled headwall Ø200 – Technical drawingAngled headwall Ø200 – Technical drawing · 1 / 25

Dimensions table

All dimensions in millimetres.

No.DiameterTotal widthTotal heightSlab thicknessOpening diameter
Front sideInner side
1200600500100200260
2300780600100300405
3300900700100300405
43001600720110300405
53002000920120300405
6400900700100400540
74001600720110400540
84001800820110400540
94002000920120400540
1040022001500140400540
114003000920120400540
12500930860100500650
135001800820110500650
145002000920120500650
1550022001500140500650
165003000920120500650
175002000920120500650
186002000920120600790
1960022001500140600790
206003000920120600790
21800200014201408001050
22800300015001408001050
2310002000142014010001270
2410003000150014010001270
2512003000180015512001470

Culverts in photos

Headwalls in our yard and after installation.

Concrete headwalls marked RoBruk in the yard1 / 9

Ask for a price

Send us your list of materials or give us a call and we will prepare a quote.

Write to us

Give us an email or phone number so we can reply.

We will use the details from this form only to reply to your enquiry.

CallDirections